3D super-resolution microscopy has never been easier. The patented single-beam light path of our EASY3D module allows you to capture the complete three dimensional structure of your sample features. Furthermore, EASY3D is compatible with any moderate- to high-NA objective lens and can correct aberrations in the STED beam, giving you full freedom to embed and image your sample in the best possible way.
super easy, super resolution
MATRIX Detector
Many eyes see more than one. The MATRIX detector drastically improves signal-to-background ratio, resolution, and dynamic range.
TIMEBOW Imaging
TIMEBOW lifetime imaging for stunning results at confocal and STED super-resolution.
FLEXPOSURE Illumination
Brings down the light dose on your sample and lables dramatically. Key ingredient for volume and live-cell superresolution.
RAYSHAPE Mirror
Dynamic aberration correction with a deformable mirror over about 200 µm z-range. 140 digital actuators adjust the mirror surface within milliseconds.
Custom Solutions
We offer solutions for even the most challenging applications. Everything that can be done, we will do.
EASY3D
bright images due to optical aberration control
Conventional 3-dimensional STED <
is often impared by aberrations caused by refractive index (RI) mismatches – reducing brightness and resolution with increasing sample depth.
> EASY3D STED with adaptive optics
corrects optical aberrations – allowing bright 3D-superresolution images at much greater depth.
EASY3D enables deep imaging of cleared adult kidney samples. Comparison of a XZ-slice deep into a renal corpuscle using conventional 3D STED imaging and EASY3D imaging. EASY3D allowed imaging up to 80 µm into cleared rat kidney tissue using an oil objective. Without correction of aberrations in the STED beam, the mismatch between immersion oil and sample leads to complete signal loss. Labels: Nephrin (red, abberior STAR 635P) and Podocin (green, AlexaFluor594).
Sample was prepared by D. Unnersjö Jess and H.G. Blom @ KTH Stockholm, Sweden.
EASY3D
why do we call it “easy”
- Tune the resolution in XY and Z to fit your imaging problem
- Use any combination of 2D or 3D STED phase plates or any user-defined phase modulation
- Aberration correction: keep the STED PSF in shape even deep inside your sample (> 20 μm)
- Switch between objective lenses on the fly: oil immersion, water immersion, silicone oil immersion…
- Resolution EASY3D: 90 × 90 × 90 nm minimum, 75 × 75 × 75 nm typical
- Resolution 2D: better than 30 × 30 nm
- Any abberior MINFLUX, INFINITY and FACILITY system can be equiped with the EASY3D device
The abberior EASY3D device uses a programmable spatial light modulator (SLM) to create phase patterns required for 2D and 3D STED microscopy. At the same time, it can also be used to correct for optical aberrations of the STED beam.
The SLM allows a revolutionary design with only one STED beam instead of two separate STED beams for lateral (XY) and axial (Z) resolution enhancement, respectively. The resolution enhancement can be tuned between pure XY and mainly Z enhancement. The single-beam design obsoletes any beam recombination and alignment resulting in outstanding system stability.
Aberrations do matter! Each and every day. This measurement impressively demonstrates the effect of refractive index mismatch. When an oil immersion lens is used to image a layer of fluorescent beads imaged through 13 μm of water, the image suffers from a significant loss in fluorescence intensity. This results in unusable images, both for confocal and for STED imaging.
In contrast, when a water immersion lens is used, both layers of beads are imaged with the same quality The abberior EASY3D design allows you to change the objective lens on the fly and to use the most suitable lens in STED mode also!
Additionally, you can further correct aberrations in all beams with our Adaptive Optics device!
The aberration correction with our programmable spatial light modulator (SLM) allows you to image with 3D STED resolution down to 180 µm into the sample! This is only possible if you can correct the Z-STED zero depending on the sample depth.
- Tune the resolution in xy and z to fit your imaging problem
- Switch between objective lenses on the fly: oil immersion, water immersion, silicone oil …
- Resolution 3D: 90 × 90 × 90 nm minimum, 75 × 75 × 75 nm typical
- Resolution 2D: better than 30 × 30 nm